Re: Radianat Heat??
Posted 10/14/2010 8:28:08 AM by Elbee I have radiant heat WITH oak hardwood floor (not engineered). I have a cement slab on my 1st floor and we gutted the floors in the kitchen/hallway/dining room. In the kitchen, we ran the tubing to chicken wire in a specific pattern then floated a cement floor over it. We then tiled it. In the dining room & hallway, we ran 'sleepers' (long 2x4's) in rows. We used a hammer drill to drill holes into the cement slab then used redhead nails to attach the sleepers to the cement. We ran the radiant in between the sleepers on reflective pex foil then filled the space with cement. We then attached the oak floors to the sleepers. DH, our friend & I did the work ourselves (except for the cement, we hired someone). It was hardwork, but doable and after almost 2 years I have NO issues of warping, or extreme expanding or contracting. In the winter you can see some contracting, but I see that in my already existing HW floors upstairs too where there is radiators and not radiant heat. We acclimated the wood to the house for a while (a month I think). As for the heat itself, my house is an icebox and those areas are the only ones that are 'warm' on even the coldest days. |